Telecommunication wires
SCART has IEC 502 shielding
APPLIED STANDARD:
JIS C 3401 - 2002; IEC 227; TCVN 5935 - 1995
OVERVIEW
+ Conductor: coarse soft in the inert gas environment
+ Structure: braided grade 2 or braided multiple soft fibers (level 5, 6)
+ Number of cores: 2 ÷ 60 cores
+ Nominal profile: from 0.5 mm2 to 22 mm2
+ Insulation / Housing: PVC / PVC
+ Type: Yes (or not) armor protection, anti-interference
+ Nominal voltage: 300 / 500V; 600V; 0.6 / 1kV
Nominal cross section area |
Conductor |
Insulation Thickness | Cover Thickness of PVC | Approx overall diameter | Insulation resistance at 70oC | Approx weight | Packed lengt | |
No of wires |
Diameter of wires |
|||||||
(mm) | (No.) | (mm) | (mm) | mm | (mm) | (V/min) | (Ω/km) | (m) |
CVV-S 2x0.5 | 7 | 0.31 | 0.8 | 1.8 | 11.7 | 36.0 | 0.2335 | 2000 |
CVV-S 2x0.75 | 7 | 0.37 | 0.8 | 1.8 | 12.1 | 24.0 | 0.2509 | 2000 |
CVV-S 2x1.0 | 7 | 0.44 | 0.8 | 1.8 | 12.5 | 18.1 | 0.2699 | 2000 |
CVV-S 2x1.5 | 7 | 0.53 | 0.8 | 1.8 | 12.9 | 12.1 | 0.2918 | 2000 |
CVV-S 2x2.5 | 7 | 0.67 | 0.8 | 1.8 | 13.9 | 7.41 | 0.3438 | 2000 |